Quality System

Quality System & Standards


The standards, traceability and management arrangements that govern the work described on this site.

StandardISO/IEC 17025:2017
Disciplines3

Overview

Calibration work is placed with laboratories holding accreditation to ISO/IEC 17025:2017. Certificates are issued under the performing laboratory's accredited scope, which is checked against the instrument before a quotation is issued.

Standards Referenced

Work described on this site is performed under ISO/IEC 17025:2017.

Accreditation named anywhere here is the performing laboratory's, and its limits are the limits of that laboratory's published scope. Measurements outside the scope are reported as non-accredited and identified on the certificate rather than quietly included. Each accreditation statement names the laboratory that holds it.

What comes with a quotation is described on the accreditation documentation page.

Metrological Traceability

Scoping a job starts by matching the instrument's range, parameter and required uncertainty against the performing laboratory's published scope of accreditation, before a quotation is issued. Accredited and non-accredited items on a single order are identified separately, both on the quote and on the resulting certificate. Measurements are traceable to the SI through NIST. The certificate states the reference standards used and the reported measurement uncertainty alongside the result. Where a statement of conformity is requested, the decision rule applied is documented on the certificate, consistent with ISO/IEC 17025:2017. Orders written around European-built machines sometimes cite VDI/VDE 2617 in place of or alongside ISO 10360; the applicable guideline is confirmed against the machine's documentation before testing.

The traceability statement belongs to the measurement, not to the building. On the certificate you will find the reference standard used, its calibration status at the time, and the chain by which it reaches the SI unit. Should that reference later fail its own calibration, the intervening work is reviewed and affected customers are contacted.

Equipment and Maintenance

Equipment categories handled include bridge, gantry and cantilever coordinate measuring machines, portable articulated arms, granite surface plates, gauge blocks, and ring and plug gauges. Out-of-tolerance findings are reported with as-found data recorded before any adjustment, supporting a reverse-traceability impact assessment back to the last passing calibration. Records, asset identifiers and due-date recall notices are retained so a certificate can be retrieved at short notice during a customer or registrar audit.

Reference equipment is uniquely identified, held under controlled conditions, and recalibrated on a defined interval that is shortened when drift data justifies it. Equipment that is damaged, overloaded, or shown to give suspect results is removed from service and labeled until it has been checked and returned to use in writing.

Management System

The work sits inside a documented management system:

  • 01

    Controlled documents

    Procedures carry issue and revision status.

  • 02

    Retained records

    Retained for a defined period and retrievable against a certificate number.

  • 03

    Audit and review

    Internal audit and management review run on a schedule.

  • 04

    Corrective action

    Nonconforming work and improvement actions are tracked to closure, and their effectiveness is checked afterwards.

Impartiality and Complaints

Risks to impartiality are identified and controlled, and results are reported on their merits regardless of the commercial outcome. Complaints and appeals are a formal input to that system โ€” the process, including the response commitment, is set out on the complaints policy page. How results should and should not be read is covered on the disclaimer page.

Looking for paperwork to support a supplier file?

Scope, method statements and traceability detail are supplied with the quotation.

A written quotation is returned by email.