Calibration and verification are two different things

Calibration establishes the relationship between a machine's indications and a reference value, with a stated uncertainty. What most shops order is performance verification: a pass/fail test against ISO 10360-2 or ASME B89.4.1, usually paired with geometric adjustment.

Where the controller allows it, an update to the volumetric error-compensation map follows adjustment. Some controllers are OEM-locked and the map cannot be touched from outside.

What a visit covers

Each calibration or reverification visit follows a fixed sequence: scales, geometry, length error, probing error, then as-left verification.

  • 01

    Scales and reader heads

    X, Y and Z scales are inspected and cleaned; reader heads are checked and adjusted for proper output.

  • 02

    Air bearings and drives

    Air bearings, airlines and drive condition are checked before geometry is tested.

  • 03

    Geometry

    Straightness, linearity and squareness are measured in the XY, ZX and ZY planes.

  • 04

    Length measurement error

    E0 and E150 tested per ISO 10360-2: five lengths, seven positions, three repeats, 105 measurements.

  • 05

    Probing error

    PFTU tested on a dedicated calibrated test sphere per ISO 10360-5, separate from the probe's own qualification sphere.

Sequence of work

  • 01

    Soak

    Thermal soak and environment check before any test begins.

  • 02

    As-found

    Length, geometry and probing error recorded before adjustment.

  • 03

    Adjustment

    Geometric correction and error-map update where the controller allows it.

  • 04

    As-left

    Verification repeated and certificate issued with before-and-after data.

Why Cleveland CMM Calibration and Repair

  • 01

    As-found and as-left both reported

    Both data sets appear on the certificate wherever adjustment occurs, supporting a reverse-traceability review.

  • 02

    Artifacts matched to the test

    Gauge blocks, step gauges and ball bars are selected to the length and orientation the standard specifies.

  • 03

    Repair alongside calibration

    Probe heads, scales, reader heads, air bearings, drives and counterbalance systems are serviced on the same visit where practical.

Coverage across Northeast Ohio and the Great Lakes region

On-site scheduling and travel terms vary by distance from Cleveland; confirm coverage for your location before booking.